← All news

Building Regulations5 min read

Part K review: BSR calls for evidence on stairs, guarding and impact

A call for evidence, not new rules. It runs from 19 October 2026 to 11 January 2027, and Approved Document K 2013 stays in place while BSR reviews it.

The Building Safety Regulator (BSR) has opened a call for evidence on Part K of the Building Regulations 2010 and its statutory guidance, Approved Document K. Part K covers protection from falling, collision and impact in and around buildings. The call opened on 19 October 2026 and, after BSR extended it from 10 to 12 weeks on 17 November 2026, now closes on Monday 11 January 2027.

This is not a consultation on new rules. BSR says plainly that the call for evidence is not proposing policy changes, and that the current requirements and guidance stay in place while the review goes on. This post sets out what is being reviewed, the research published alongside it, and how a quick stair geometry check relates to the guidance as it stands today.

Update pending

The call for evidence now closes on 11 January 2027 (extended on 17 November 2026 from the original 28 December 2026 date). BSR has not said when it will publish a summary of responses or any next steps. We will check the gov.uk and BSR pages again by 29 January 2027 and update this post with anything that has been published by then.

What Part K and Approved Document K cover

Part K sits in Schedule 1 to the Building Regulations 2010, which apply in England. Approved Document K gives statutory guidance on ways to meet it. BSR lists the topics it covers as:

  • stairs, ladders and ramps;
  • handrails, guarding and protection from falls;
  • windows, doors and gates, including glazing;
  • vehicle barriers and loading bays.

BSR notes that it has been more than 20 years since Part K and Approved Document K last had a substantial review. The current Approved Document K is the 2013 edition.

Why BSR is reviewing it

Under the Building Safety Act 2022, BSR has a duty to keep the safety of people in and about buildings, and the standard of buildings in England, under review. Reviewing Part K is one part of that wider programme.

BSR says it wants to find out whether the current requirements and guidance work, and whether any areas need more clarity, strengthening, research or development. It is asking for evidence, examples, case studies and practical experience. That includes comments on the diagrams, tables and referenced standards in Approved Document K. BSR also invites comment on issues stakeholders have already raised, such as whether guidance is consistent across the Approved Documents and how falls are prevented in different building types.

BSR says any future proposals to change the regulations or the statutory guidance would go to a further consultation. Some issues may need longer-term work.

The research published alongside it

BSR points to four research reports, published by BSR, the Ministry of Housing, Communities and Local Government and HSE, that form part of the evidence base for the review:

  • Evidence to support potential changes to Approved Document K guidance on domestic stairs (published on gov.uk on 28 October 2025). This report covers domestic stair design, including step dimensions, consistency and handrails. Government says its findings and recommendations are not government policy or guidance.
  • Approved Document K: general access and utility stairs (published on gov.uk on 14 October 2026). It looks at how proposed changes to stair dimensions could affect safety and fall risk, and compares the current guidance with relevant British Standards.
  • HSE RR1219, a study of how well guarding prevents falls through window openings.
  • HSE RR1228, a mixed-methods study of the safety of limited-access stairs in dwellings.

We do not summarise the reports’ recommendations here. They are research, not guidance, and nothing in them changes what Approved Document K says today. Anyone designing stairs or guarding should read them as background, not as new limits.

A worked example: today’s Table 1.1 figures

Stair geometry is the part of Approved Document K that most often turns up in early design. Our stair rise and going calculator screens a step against the Table 1.1 ranges in the 2013 edition, for the stair category you choose. It is useful for showing how much the category matters.

EXAMPLE

A flight rises 2,650 mm floor to floor. We tried two step layouts in the calculator.

  • Target rise 200 mm, going 225 mm. The calculator rounds up to 14 equal risers of 189.3 mm, with 13 goings and 2,925 mm on plan. Pitch is 40.1° and 2R + G is 604 mm. As a private stair, every check is inside the Table 1.1 figures. As a general access stair, the rise is outside 150–170 mm and the going is outside 250–400 mm.
  • Target rise 170 mm, going 280 mm, general access. The flight becomes 16 risers of 165.6 mm, with 15 goings and 4,200 mm on plan. Pitch is 30.6° and 2R + G is 611 mm. Every check is inside the general access figures.

Meeting the general access figures in this example needs about 1,275 mm more length on plan. Check your own flight in the stair calculator.

This is a geometry screen against the current guidance, nothing more. It does not check headroom, width, landings, handrails, guarding or tapered treads, and it does not cover Wales, Scotland or Northern Ireland, which have their own guidance. If BSR’s review leads to revised figures, those would be consulted on first, and the calculator would be updated only once a new edition is actually published.

What this means for a live project

  • Nothing changes yet. Approved Document K, 2013 edition, remains the statutory guidance in England. Design and building control submissions should carry on referencing it.
  • The research is worth knowing about. Designers working on stairs, guarding or window openings may find the evidence useful background, especially where a design sits close to the edge of a range.
  • You can respond. BSR welcomes responses from building control bodies, architects and designers, engineers, contractors, manufacturers, building owners and managers, trade associations, standards bodies and anyone else with relevant experience. The online survey is the preferred route, and BSR says it takes between 10 and 45 minutes. BSR also accepts responses by email or post.

Our setting-out logic guide covers how rise, going and gradient figures fit into early geometry checks.

Illustrative only. Not design advice.

Sources

More from News

Electrical5 min read

BS 7671:2018+A4:2026 is now the current edition

The six-month overlap has ended. What the IET and BSI say changed in Amendment 4 (batteries, PoE, ICT functional earthing and medical locations), and why voltage drop matters more at extra-low voltage.

Read post →

← All news