A mechanical figure on this site answers one equation. Pump power is ρgQH. Shaft power is torque times angular speed. Neither selects a machine.
The two equations
Hydraulic power is ρgQH. Density ρ is in kilograms per cubic metre, Q is flow in cubic metres per second and H is head in metres. Shaft power divides that hydraulic power by the efficiency you type, as a fraction. The efficiency is your assumption. It is not read from a pump curve on this site.
Power from torque is P = Tω, and ω = 2πn/60 when speed is in revolutions per minute. In convenient units, kilowatts are newton-metres times rpm, divided by 9,549. The torque is the steady torque at that speed. It is not a starting torque and not a gearbox rating.
What still sits outside
Net positive suction head, efficiency at the real duty and the motor frame are read from the manufacturer’s curve. Two pumps in parallel, a variable-speed drive and a system curve that is not a single head all move the duty. Starting current and service factor are outside the equation.
Write flow, head, density and efficiency next to a pump figure, or torque and speed next to a shaft figure. Without those inputs the kilowatt number cannot be reviewed. A 5.5 kW motor on the worked duty is only the next question, not the answer.
What to do with the number
Use it to see whether a duty is in the right order: a few kilowatts, or tens. Then open the manufacturer curve. The curve carries NPSH, efficiency at that duty, and the motor frame. This site does not.
Worked duty
0.02 m³/s through 15 m of head, water, 70% pump efficiency, is 2.94 kW hydraulic and 4.20 kW at the shaft. A 5.5 kW motor might be the next question. It is not the answer. Starting current, service factor and the system curve still sit outside the equation.
Scope: this guide is about reviewing a pump or motor figure before selection. For the gear, torque and shaft-power chain, see setting-out logic; for the pipe losses that feed the head, see pipework.
The duty point is where two curves meet
A pump does not deliver a fixed flow. It runs where its own head–flow curve crosses the system curve, which is the static lift plus losses that grow roughly with the square of the flow. For the worked main, H ≈ 15 + kQ², and the combined straight-pipe and fittings loss of about 0.92 m at 0.02 m³/s gives k ≈ 2,300. At 0.016 m³/s the system needs only about 15.6 m. If the selected pump’s curve passes above the duty point, the system settles at a higher flow than intended and draws more power.
Speed control and the affinity laws
For a centrifugal pump on the same system, flow varies with speed, head with speed squared and power with speed cubed. Running the worked pump at 80% speed gives about 80% flow, 64% head and 51% power: the 4.20 kW shaft figure would fall to about 2.15 kW. These ratios hold well when the system is mostly friction. With a large static lift, as here, the head at reduced speed may fall below the 15 m lift and the flow drops much faster than the laws suggest, so check against the system curve.
| Speed | Flow | Head | Power |
|---|---|---|---|
| 100% | 100% | 100% | 100% |
| 90% | 90% | 81% | 73% |
| 80% | 80% | 64% | 51% |
| 70% | 70% | 49% | 34% |
Suction conditions
A pump can cavitate if the pressure at its inlet falls too low. The net positive suction head available is atmospheric head, plus or minus the static height of the water surface above or below the pump, minus vapour pressure head and suction losses. For water at 20°C with a 2 m suction lift and 0.3 m of suction loss, it is about 10.33 − 2 − 0.24 − 0.3 ≈ 7.8 m. That must exceed the pump’s required value from its curve, with a margin.
Questions
Can I pick the motor from the shaft power?
Only as a first look. Check the shaft power across the operating range on the pump curve, allow a margin and choose the next standard size. 4.20 kW might point to 5.5 kW, but the curve decides.
Why is efficiency so important?
Running cost follows the input power for thousands of hours a year. A pump at 60% instead of 70% efficiency uses about 17% more energy for the same duty.
What is a system curve?
The head the system needs at each flow: static lift plus losses rising with flow squared.
Why might a pump be oversized?
Margins added at several stages, on head, flow and motor size, compound. An oversized pump runs away from its best efficiency point, wastes energy and can be noisy. Check the margins against the duty point.
Open the pump power calculator or the shaft power calculator.
Related: Duct air velocity
See also: modelling a spring in SolidWorks.
Sources
Last checked 14 October 2026. Original guidance. Standards text stays with the publisher.