Pump power calculator
Water or another liquid, steady flow. Pipe losses are not calculated here — put the head you already have.
Worked examples
Example 1: Circulating pump
0.02 m³/s against 15 m, water, 70% efficiency: Ph = 1,000 × 9.81 × 0.02 × 15 = 2.94 kW, shaft 4.20 kW.
Example 2: Booster set
8 L/s (0.008 m³/s) against 32 m, water, 62% efficiency: Ph = 2.51 kW, shaft 4.05 kW. Less flow but twice the head gives a similar shaft power.
Reading the result
H must be the total head at the duty point: static lift plus friction and fitting losses. A static lift alone understates the duty.
Motor input is higher again by the motor efficiency, and motors are chosen from standard sizes with a margin. The pump curve and the system curve decide the real duty point.
Common mistakes
- Entering flow in L/s or m³/h in the m³/s box. 8 L/s is 0.008 m³/s; 28.8 m³/h is also 0.008 m³/s.
- Using the static lift only, without pipe and fitting losses.
- Entering efficiency as a fraction (0.7) instead of a percentage (70).
- Treating shaft power as motor rating: add motor efficiency and a sizing margin.
- Forgetting density for liquids other than water.
How to use
Enter the flow in m³/s, the total head in metres, the pump efficiency in percent and the fluid density. The result is the hydraulic power ρgQH and the shaft power divided by efficiency.
Edge cases
- Efficiency must be greater than 0 and no more than 100%. Flow and head cannot be negative.
- The head must be the total head, including friction losses, not just the static lift.
- Motor efficiency is separate. The electrical input is the shaft power divided by the motor efficiency.
Questions
What does 0.005 m³/s against 30 m at 60% need?
About 1.47 kW hydraulic and 2.45 kW at the shaft.
Where do I get friction loss?
Use pipe flow and add the result to the static head, as in the fluid logic chain.
How do I size the motor from this?
Take the shaft power at the duty point, check it across the range of flows the pump will see, and choose the next standard motor size above the highest figure. The pump curve, not this page, gives the power at other flows.
Basis
This tool uses the formula shown under Method. It is standard arithmetic or physics and relies on no external data set or design standard, so check any values you enter against your own project data.
Last checked 14 October 2026. A scenario, not a design. See methodology, standards and the disclaimer.