Formwork concrete pressure calculator
The pressure if concrete behaved as a liquid to the full pour height. Real design pressure is often lower.
Worked examples
Example 1: Wall pour
25 kN/m³ over 3 m of fluid concrete gives 75 kN/m² at the base.
Example 2: Tall column poured in one lift
24 kN/m³ over 4.5 m gives 108 kN/m². A column filled quickly can stay fully fluid, so the full hydrostatic value is a sensible design assumption for a fast pour.
Reading the result
Full hydrostatic pressure is an upper bound. On slower pours the concrete stiffens and the pressure at depth can be lower. CIRIA Report 108 gives a method using rate of rise, temperature, section size and concrete type. Select it above: P = D[C₁√R + C₂K√(H − C₁√R)], with K = (36/(T + 16))², limited to the hydrostatic value.
Self-compacting concrete and retarded mixes are normally designed for full hydrostatic pressure.
Common mistakes
- Using the pour height when only part is still fluid, or vice versa.
- Forgetting that vibration reliquefies concrete.
- Using a slow-pour reduction for SCC.
How to use
Enter the vertical height of concrete that is still fluid, in metres, and the unit weight of the concrete in kN/m³. The result is the full hydrostatic pressure at the base, an upper bound.
Edge cases
- Zero height gives zero pressure. Negative values are rejected.
- For a pour that stiffens as it rises, the design pressure from CIRIA Report 108 can be lower than this bound.
- Self-compacting concrete and retarded mixes can stay fluid for the full height, so the hydrostatic bound applies.
Questions
What does a 2.4 m wall at 24 kN/m³ give?
About 57.6 kN/m² at the base.
And a 4.5 m column at 25 kN/m³?
112.5 kN/m², a large load for formwork ties.
What else loads formwork?
Wind, the weight of the formwork itself, construction loads from people and equipment, and impact from discharging concrete. Vibration keeps concrete fluid near the poker, so the hydrostatic zone can extend further than expected. These loads are combined in the formwork design, not in this page.
Does the pressure act on the whole face?
In the hydrostatic bound it increases linearly with depth, from zero at the top to the maximum at the base. The total force per metre run of wall is half the base pressure times the height: 75 kN/m² over 3 m gives 112.5 kN per metre.
Sources
- CIRIA Report 108, Concrete pressure on formwork (1985)
- BS 5975-2:2024, falsework design and implementation
Last checked 14 October 2026. Design pressure methods: CIRIA Report 108 (1985). Procedure: BS 5975-1:2024 and BS 5975-2:2024. A scenario, not a design. See methodology, standards and the disclaimer.