Home · Calculators

Slab prop load calculator (tributary area)

A tributary area screen for interior props. Not a falsework design and not a prop capacity check.

Preliminary only. Prop loads must be confirmed by the temporary works designer and checked by the temporary works coordinator.

Worked examples

EXAMPLE 1: 250 mm slab

t = 250 mm, γ = 26 kN/m³, formwork 0.5 and construction load 1.5 kN/m² (EXAMPLE). q = 6.5 + 0.5 + 1.5 = 8.5 kN/m². Props at 1.2 × 1.2 m: P = 8.5 × 1.44 = 12.24 kN per prop, unfactored.

EXAMPLE 2: 300 mm slab, wider grid

t = 300 mm: q = 7.8 + 0.5 + 1.5 = 9.8 kN/m². Grid 1.5 × 1.2 m: P = 9.8 × 1.8 = 17.64 kN per prop, unfactored.

Reading the result

Compare the result only with capacities the temporary works design allows; prop capacity depends on extension, end conditions, out-of-plumb and bracing, and is not checked here. Edge props and props under beams or drops carry different areas. Back-propping to slabs below is a separate question.

The load is unfactored. Whether factors are applied, and which, is set by the design method the temporary works designer uses.

Common mistakes

  • Using 24 kN/m³ for fresh reinforced concrete.
  • Leaving out construction load or formwork weight.
  • Using an interior tributary area for edge or beam props.
  • Reading a prop’s closed-height capacity when it is extended.
  • Treating this screen as a temporary works design.

How to use

Enter the slab thickness in millimetres, the fresh unit weight, formwork and construction loads from the temporary works design, and the prop spacings in metres in each direction.

Edge cases

  • Thickness, unit weight and spacings must be greater than zero; formwork and construction loads may be zero.
  • Only interior props on a regular grid are covered.
  • No capacity, bracing or stability check is made.
  • Inputs over 10¹² are rejected.

Questions

Where do the construction loads come from?

From BS EN 1991-1-6 and the UK National Annex, as applied by the temporary works designer. The defaults here are EXAMPLE values.

Does this cover back-propping?

No. Loads shared with slabs below need a separate assessment.

Why 26 kN/m³?

BS EN 1991-1-1 Table A.1 gives 24 for normal-weight concrete, +1 for reinforcement and +1 for unhardened concrete.

Sources

Last checked 17 October 2026. Preliminary figure only. See methodology and the disclaimer.