Ohm's law, resistor and voltage divider calculator

Three common DC circuit sums in one place.

Not for cable sizing, motor starting or any circuit with reactance.

A network screen for ideal, fixed resistors. It does not size a resistor for a product, cover tolerance stacking or heating, or replace a circuit simulation.

Ohm's law

Worked examples

Example 1: Heater element

230 V across 46 Ω draws 5 A and dissipates 1,150 W.

Example 2: Low-voltage circuit

12 V and a measured 0.5 A give 24 Ω and 6 W. If the current doubled at the same voltage, the resistance would have halved.

Reading the result

Real AC loads with motors, transformers or electronics have reactance, so current and power do not follow V = IR. Use the power-factor pages for those.

Resistance of a conductor rises with temperature. A cold heater element measures lower than it runs.

Ohm’s law is exact for resistive elements at a fixed temperature. It underpins voltage-drop, divider and heater calculations elsewhere on the site.

Typical values

Known pairFormula
V and RI = V / R
V and IR = V / I
I and RV = I × R
Any pairP = V × I = I²R = V²/R

Common mistakes

  • Entering three values, which over-specifies the circuit.
  • Using AC values for reactive loads.
  • Using milliamps in the amp box.

How to use

Enter any two of voltage, current and resistance. Leave the third blank. The result fills in the third and shows the power.

Edge cases

  • Exactly two values are needed. Entering all three or only one gives a message.
  • A resistance of zero with a voltage is rejected, because the current would be infinite.
  • The relationship is for resistive DC or for the resistive part of an AC circuit.

Questions

What resistance does a 2 kW heater at 230 V have?

R = V²/P ≈ 26.5 Ω, drawing about 8.7 A.

What does 12 V and 0.5 A give?

24 Ω and 6 W.

Does this work for AC?

For a purely resistive load, yes, using RMS values. For loads with inductance or capacitance, the opposition to current is impedance, not resistance, and current and voltage are out of phase. Use the power factor pages for those.

Why does a lamp’s resistance seem to change?

Filament and many other resistances rise with temperature. A cold filament can have a fraction of its hot resistance, so the switch-on current is much higher than the running current. Ohm’s law holds at each instant, but R is not constant.

Series and parallel resistors

How it differs from Ohm’s law

The Ohm’s law calculator treats one resistance and finds the missing value of V, I or R. This page works on a network: it first reduces two or three parts to one equivalent resistance, then shows how a supply divides across them. Use Ohm’s law when you already have a single resistance; use this page when you have several and need the equivalent or the share each part takes. For the voltage at the midpoint of two series resistors with a load attached, the voltage divider is the closer tool.

Worked examples

EXAMPLE 1: 10 Ω and 15 Ω on 12 V

Series: 25 Ω, so 12 / 25 = 0.48 A flows through both. R1 takes 4.8 V and 2.304 W; R2 takes 7.2 V and 3.456 W, 5.76 W in total. Parallel: 10 × 15 / 25 = 6 Ω. R1 carries 1.2 A (14.4 W), R2 carries 0.8 A (9.6 W), and the supply gives 2 A and 24 W. The same two parts dissipate more than four times as much in parallel.

EXAMPLE 2: 220 Ω, 330 Ω and 470 Ω on 5 V

Series: 1,020 Ω and 4.90 mA, with 1.078 V, 1.618 V and 2.304 V across the three parts (they add back to 5 V). Parallel: 1/(1/220 + 1/330 + 1/470) = 103.06 Ω. Branch currents are 22.73, 15.15 and 10.64 mA, total 48.52 mA, and the 220 Ω part dissipates the most at 113.6 mW.

When to use it

  • Making up a value that is not in the E-series range from two stock parts.
  • Checking a heater or load bank built from several elements.
  • Seeing which part of a series string drops the most voltage, or which branch carries the most current.
  • Sanity-checking a meter reading across a network before looking for a fault.

Reading the result

In series the largest resistor takes the largest share of the voltage and the heat. In parallel it is the other way round: the smallest resistor carries the most current and gets hottest. Compare each power figure with the part’s rating, and allow a margin; derating with temperature is a matter for the manufacturer’s data.

Typical values

CombinationEquivalent
n equal resistors R in seriesnR
n equal resistors R in parallelR/n
100 Ω ∥ 100 Ω50 Ω
10 Ω ∥ 1 kΩ9.90 Ω (the small part dominates)
1 kΩ + 10 Ω1,010 Ω (the large part dominates)

Common mistakes

  • Adding parallel resistances directly instead of adding their reciprocals.
  • Expecting a parallel result above the smallest resistor. It is always below it.
  • Checking only the total power and not the hottest individual part.
  • Entering kΩ values as ohms, which puts every current out by a factor of 1,000.
  • Treating a mixed network (some parts in series, some in parallel) as one or the other. Reduce it in stages.

How to use

Enter R1 and R2 in ohms, and R3 if there is a third part. Add a supply voltage to see the split in both arrangements; leave it blank if you only need the equivalent resistance.

Edge cases

  • R1 and R2 must be greater than zero. A blank R3 is ignored; zero or negative values are rejected, because a 0 Ω link in parallel shorts the whole group.
  • A supply of 0 V gives zero current and power everywhere.
  • For four or more parts, combine three here, then enter that result as R1 with the rest.
  • Values above 10¹² are rejected.

Questions

What do 4.7 kΩ and 10 kΩ give in parallel?

4,700 × 10,000 / 14,700 ≈ 3,197 Ω, about 3.2 kΩ.

How does tolerance affect the result?

Two ±5% parts in series give a total within ±5% of nominal; in parallel the same applies. The calculator uses nominal values only, so if the ratio matters, as in a divider, use closer-tolerance parts or check both ends of the band.

Why does the parallel case get so much hotter?

Each branch sees the full supply voltage, and power rises with V²/R. In series the voltage is shared, so each part sees only part of it.

Voltage divider

Worked examples

Example 1: 12 V

12 V, R1 1 kΩ, R2 2 kΩ: Vout = 8 V.

Example 2: 5 V sensor input

5 V, R1 10 kΩ, R2 4.7 kΩ: Vout = 1.60 V.

Reading the result

Any load connected to the output acts in parallel with R2 and pulls the voltage down.

A divider is not a power supply.

A loaded divider sags because the load and R₂ act in parallel. Keep the load resistance at least ten times R₂ if you want the unloaded figure to stay within about 10%.

Typical values

R₁ : R₂Vout as a fraction of Vin
1 : 10.50
1 : 20.67
2 : 10.33
10 k : 4.7 k0.32

Common mistakes

  • Swapping R₁ and R₂ (the output is taken across R₂).
  • Ignoring the load connected to the output, which forms a parallel path with R₂.
  • Using a divider to power a device rather than to set a reference or scale a signal.

How to use

Enter the input voltage and the two resistors: R1 on top, R2 at the bottom. The result is the unloaded output Vout = Vin × R2 / (R1 + R2).

Edge cases

  • Negative resistances are rejected. If both resistors are zero, there is no finite answer and the tool says so.
  • Negative input voltage is allowed and gives a negative output.
  • Any load connected to the output acts in parallel with R2 and pulls the output down.

Questions

What does 5 V across two 10 kΩ resistors give?

2.5 V unloaded. Connect a 10 kΩ load across R2 and the bottom becomes 5 kΩ, so the output drops to about 1.67 V.

Can a divider power a device?

Not reliably. Use a regulator; a divider is for references and sensing.

How do I pick resistor values?

The ratio sets the output; the size sets the current. Two 10 kΩ resistors across 5 V draw 0.25 mA, which is small. Two 100 Ω resistors give the same 2.5 V but draw 25 mA and waste 125 mW. Pick values large enough to keep the current low but small compared with any load on the output.

Sources