Home · Calculators

UK steel section tables and finder

Dimensions and properties for universal beams and columns, with a lightest-section search.

Find the lightest section (optional)

How to use it

Pick a family and a size to read its properties. To size a member, enter the I or Wpl,y your calculation needs, and the tool lists the lightest sizes that meet it. Add a maximum depth if you have a headroom limit.

Which axis is which

The y axis is the major axis and the z axis is the minor axis, following Eurocode notation. A beam bending under gravity normally bends about y. A column without intermediate restraint normally buckles about z.

Use these figures in the beam deflection and Euler buckling tools, which have the same picker. The steel weight tool gives the mass of a length.

Worked examples

Reading a section

A 457 × 191 × 67 UB weighs 67.1 kg/m and has Iy = 29,597 cm⁴ and Wpl,y = 1,481 cm³. Its radii of gyration are √(29,597 ÷ 86) = 18.6 cm about the major axis and √(1,452 ÷ 86) = 4.1 cm about the minor axis. The much smaller minor-axis value is why an unrestrained section of this shape buckles about z.

Finding the lightest section

Enter a minimum Iy of 30,000 cm⁴ and the finder returns 533 × 165 × 66 UB at 65.7 kg/m, which is 524.7 mm deep. Add a maximum depth of 460 mm and it returns 457 × 191 × 74 UB at 74.3 kg/m. The headroom limit costs 8.6 kg on every metre of beam.

Starting from a deflection limit

A simply supported 6 m span carries 8 kN/m. Taking E = 210 kN/mm² and, for this example, a limit of span ÷ 360 = 16.7 mm, the formula δ = 5wL⁴ ÷ 384EI needs I ≥ 3,857 cm⁴. The finder gives 305 × 102 × 25 UB at 24.8 kg/m, with Iy = 4,455 cm⁴. The check does not include the beam's own weight, or strength and stability, so a real design may need something larger.

Common mistakes

  • Mixing units. 1 cm⁴ is 10,000 mm⁴, and these tables use cm⁴ and cm³.
  • Using Iy for a column that is free to buckle about the minor axis.
  • Comparing sections by depth alone. A deeper section is often lighter for the same stiffness.
  • Choosing the lightest section without checking it can be bought in the length and quantity you need.

Questions

What does 457 × 191 × 67 mean?

It is a serial size of about 457 mm deep and 191 mm wide, weighing about 67 kg per metre. The actual dimensions differ slightly, and the table gives them.

When would I choose a UC over a UB?

Universal columns are nearly as wide as they are deep, so they resist buckling about the minor axis better. Universal beams put more material in the flanges further from the neutral axis, so they are more efficient in bending.

Which sizes are included

The lookup covers the universal beam and column sizes listed by British Steel. A size from another mill or an older table may differ slightly, so confirm the figures with your supplier before you rely on them. Open the datasheets under Sources for the complete published tables.

What this does not do

It does not check bending resistance, shear, lateral torsional buckling or connections. Those need a design to BS EN 1993-1-1 by a competent engineer, using the current tables from your steel supplier.

Sources

Last checked 9 November 2026. See the methodology and the disclaimer.