Home · Calculators

ISO 19650 status code lookup

What a code means in each edition of the UK National Annex.

Why the edition matters

The same code can mean something different in each edition. S4 was stage approval in 2018 and is review and authorisation in 2021. S5 was withdrawn in 2018 and is back in 2021 for review and acceptance. S6 and S7 went the other way. Check which edition your project information standard adopts before relying on a code.

2021 revision

CodeMeaningNote
S0Developed within a task teamWork in progress
S1Suitable for coordinationPreliminary revision
S2Suitable for information or referencePreliminary revision
S3Suitable for review and commentPreliminary revision
S4Suitable for review and authorisationPreliminary revision
S5Suitable for review and acceptancePreliminary revision
S6Withdrawn in this revisionNot used
S7Withdrawn in this revisionNot used
AnAuthorisation or acceptance, A1, A2 and so onContractual revision
BnDeprecated in this revisionNot used
CRWithdrawn in this revisionUse A6 for as-constructed information

2018 edition

CodeMeaningNote
S0Initial statusPreliminary revision and version
S1Suitable for coordinationPreliminary revision
S2Suitable for informationPreliminary revision
S3Suitable for review and commentPreliminary revision
S4Suitable for stage approvalPreliminary revision
S5WithdrawnNot used
S6Suitable for PIM authorizationPreliminary revision
S7Suitable for AIM authorizationPreliminary revision
AnAuthorized and accepted, A1, A2 and so onContractual revision
BnPartial sign-off, B1, B2 and so onPreliminary revision
CRAs constructed recordContractual revision

A status code shows what a container may be used for. It does not show that the content has been checked. For how the codes sit with the common data environment, read CDE states explained.

What changed in 2021

Code2018 edition2021 revision
S0Initial statusDeveloped within a task team
S4Stage approvalReview and authorisation
S5WithdrawnReview and acceptance
S6, S7PIM and AIM authorizationWithdrawn
A1 to AnAuthorized and acceptedAuthorisation or acceptance
B1 to BnPartial sign-offDeprecated
CRAs constructed recordWithdrawn, use A6 for as-constructed information

Reading a code on a real project

  • A drawing at S2 can be used for information, but it hasn't been offered for coordination or comment.
  • An S3 container invites comment. Comments go back to the author, and the revised version is shared again.
  • S4 means different things by edition, so a team working to the 2018 annex and one working to 2021 could disagree about what it asks for.
  • Moving a container from one code to another is a controlled step in the common data environment, not a rename.

Common mistakes

  • Assuming a project follows the 2021 revision without checking its information standard.
  • Using S6, S7 or CR on a project working to the 2021 revision.
  • Treating a status code as proof that a technical check has taken place.

Questions

Can a project use its own codes?

Projects sometimes add codes, and the information standard should define them. This tool only knows the codes in the National Annex tables.

Why does A appear as An?

The number after A is set by the project, usually to match a stage or milestone, so A1, A2 and so on share one meaning.

Sources

Last checked 9 November 2026. See the methodology and the disclaimer.